Our low profile load cells are ideal for a range of structural and industrial applications where height may be limited and high accuracy is important.
They have a high resistance to offset loads which is particularly useful in industrial weighing applications where true central loading cannot be guaranteed.
Manufactured from high tensile stainless steel, the standard fixing arrangement includes six counter bored holes with an optional base plate that enables the low profile load cells to become an integral part of the structures they are monitoring.
Our load cells can also be supplied with centrally bored or tapped holes for more specialist installations.
Features and benefits of low profile load cells:
- Designed and manufactured in the UK for high quality assurance
- Robust construction for use in hostile environments
- Easy to install, operate and remove
- Highly accurate and reliable
- Long design life with corrosion protection
- Bespoke solutions tailored to your specific needs
- Supplied with full certificate of calibration
- High resistance to offset loads
Cabled low profile compression load cell typical specifications:
mV/V output | mA output | |
---|---|---|
Rated load | As required | As required |
Proof load | 150% of rate load | 150% of rate load |
Non-linearity | < ±0.25% of full scale | < ±0.25% of full scale |
Non-repeatability | < ± 0.05% of full scale | < ± 0.05% of full scale |
Zero balance | < ± 0.05% of full scale | < ± 0.05% of full scale |
Environmental protection | IP68 | IP68 |
Safety factor | As required | As required |
Operating temperature range | -20oC to +60oC | -20oC to +60oC |
Storagetemperature range | -30oC to +80oC | -30oC to +80oC |
Cableconnection | Gland or connector | Gland or connector |
Cablelength | 5m as standard | 5m as standard |
Outputsignal | mV/V | 4-20mA |
Electrical connection | 4 core | 2 or 3 wire |
Recommended excitation voltage | 10V | N/A |
Maximum excitation voltage | 15V | N/A |
Recommended supply voltage | N/A | 24V |
Maximum supply voltage | N/A | 30V |
Bridge resistance | 700 Ohm | N/A |
Sensitivity | 1.5mV/V - 2.0mV/V nominal | N/A |
Wireless low profile compression load cell typical specifications:
Wireless output | |
---|---|
Ratedload | As required |
Proofload | 150% of rate load |
Non-linearity | < ±0.25% of full scale |
Non-repeatability | < ± 0.05% of full scale |
Zerobalance | < ± 0.05% of full scale |
Environmentalprotection | IP66 |
Safetyfactor | As required |
Operatingtemperature range | -20oC to +60oC |
Storage temperaturerange | -30oC to +80oC |
Outputsignal | Wireless (input signal mV/V) |
Datalogging | In interface |
Batterytype | 3 x D |
Activebattery life | Up to 500 hours |
Standbybattery life | Up to 1700 hours |
Telemetryfrequency | 2.4Ghz ISM |
System range | Up to 350m |
Samplingrate | 10Hz (500Hz max) |
Low profile compression load cell typical dimensions:
Load rating (tonnes) | A mm | B mm | C mm | D mm | H Hole | |
---|---|---|---|---|---|---|
DIA 2800 | 0.1 to 20 |
112 |
25 |
11 |
50 |
To suit 6 x M6 SKT CAP screws on 98 P.C.D |
DIA 3356 |
10 to 50 |
150 |
45 |
12 |
60 |
To suit 6 x M6 SKT CAP screws on 122 P.C.D |
DIA 3357 | 40 to 100 | 184 | 53 | 12 | 70 | To suite 6 x M6 SKT CAP screws on 146 P.C.D |
Available options:
- Cabled and wireless options
- Environmentally sealed to IP66 or IP68
- Can be used singularly or in sets
- Supplied with either centrally bored or tapped holes
- Base plate optional