The AXILOG is a state-of-the-art vibration monitoring system designed to quantify the load and determine the risk of damage on buildings and other structures.
The AXILOG II system is easy to operate, providing real-time measurements of vibration levels in accordance with BS, SBR or DIN guidelines with the advantage of remote monitoring. It provides simultaneous readings of object velocity in the X, Y and Z directions, which can be presented in a variety of formats and printed with site annotations.
Multiple alarm levels can be programmed into the system, providing the operator with an early warning in the event of pre-set levels being exceeded. The automated reporting function and significantly improved battery life makes this product ideal for long-term monitoring.
A lightweight and highly accurate system, the AXILOG II is supplied with a two year calibration certificate and rugged carry case.
Benefits of the AXILOG II vibration monitoring system:
- Real-time remote monitoring
- Built in modem as standard
- Multiple alarm notifications for important events
- Automatically generates reports for easy long-term monitoring
- Rugged lightweight system
- Up to 3 months internal battery life
- Built in GPS sensor to record location
- Free software updates
- Easy to operate
- Full equipment training available
- Complete test package available
| All of our equipment is fully calibrated to UK national standards. | |
|---|---|
| Measurements | |
| Velocity direction | X, Y, Z |
| Velocity range | 0 to 50mm/s - 0.8 to 100Hz |
| Velocity resolution | 0.01mm/s |
| Sensor type | Geophone |
| Signal processing method | Digital filter |
| Dominant frequency determination | FFT |
| GPS location sensor | GPS receiver, in sensorhousing |
| GPS location accuracy | 10m CEP |
| Sensor tilt | Digital spirit level, insensor housing |
| Sensor tilt accuracy | ±0.1o |
| Data logging settings | |
| Logging interval time | 2 to 120 seconds |
| Trigger level (minimum logging level) | 0.01 to 50mm/s |
| Applicable standard | SBR-A, SBR-B, DIN45669B,BS5528-2, BS7385-2 |
| Memory configuration | Circular or linear |
| Alarm settings | |
| Number of alarm levels | Two |
| Alarm level curve | Absolute value, SBR /DIN / BS curves or user curve |
| Frequency dependent curves | ALL SBR / DIN / BScurves are integrated |
| Alarm message type | Electrical contact,email and / or SMS, contact server |
| Number of messages per alarm | Three contacts with twoemail addresses and two SMS numbers each |
| Online features | Contact remote server ifan alarm occurs |
| Online functionality | |
| Management | Status, alarms and eventoverview or each AXILOG system |
| Real-time capabilities | Graphs updated includingspectrum every two seconds |
| Alarm logging on screenand in event log | |
| Status overview -logging on / off, battery condition, error status | |
| Data acquisition | Read / erase memory |
| Read / erase event log | |
| Set logging parameters | |
| Set modem schedule | |
| Control | Start / stop loggingeither manual or with time schedule |
| Alarms triggered byabsolute values, reference standard curves or user curves | |
| Monitoring type - eitherBS, DIN or SBR | |
| Alarm action - eithersend e-mail of SMS | |
| Set event messages andsend by email or SMS | |
| Language settings | English, Dutch andGerman |
| Display | 2 x LCD backlit displaysfor measurements and for settings |
| Battery | Lithium-ion 35 Ahcapacity |
| Battery charge | Mains or car battery |
| Battery charge time | 12 hours (after fulldischarge) |
| Connections | Mini USB / Alarm /Charger / Sensor / External antenna |
| Modem | Mini SIM (2FF), GPRS/3Gnetwork, internal antenna and optional external antenna |
| Environmental protection | IP65 (logger and sensor) |
| Temperature operating range | -10oC to +50oC |
| Temperature storage range | -20oC to +60oC |
Send email, SMS or contact the server at the following events:
- Primary alarm
- Secondary alarm
- Power ON
- Battery empty
- Charger connected / disconnected
- GPS obtained
- Sensor disconnected
- Sensor shock
- IP obtained
- Registration started / stopped
- Server connection
- Memory almost full / completely full
- GSM access failure
- Email send failure
- Server connect failure
The AXILOG software enables automatic read-out and reporting directly from the AXILOG unit or remotely.
Data can be presented in a number of formats including:
- Peak particle velocity vs. time
- Peak particle velocity vs. frequency – with BS, SBR and DIN standards overlay
- Frequency vs. time
- Time vs. velocity – histogram of event duration
How the AXILOG II works:
- Set the times, actions and desired report layout per AXILOG system
- Set the monitoring period (start and end time)
- Set the time at which the AXILOG must contact your PC
- As soon as the AXILOG contacts the PC, the data is downloaded
- As soon as the download ends, the report is generated